Development and validation of Dosobuvir In RP- HPLC

Authors

  • Sruthi L Department of Pharmaceutical analysis, Mother Teresa college of Pharmacy,Ghatkesar, Medchal Telangana-501301
  • Kiran kumar V Professor,Department of Pharmaceutical analysis, Mother Teresa college of Pharmacy,Ghatkesar ,Medchal Telangana-501301
  • Aravinda Reddy P Principal, Mother Teresa college of Pharmacy,Ghatkesar ,Medchal Telangana-501301

Keywords:

RP- HPLC, Dobosuvir

Abstract

RP HPLC approach, which is simple, explicit, genuine, and unique for evaluating dobutamine and its cycle-related pollutant in mass and drug dose systems, is the focus of the most recent work. A thorough composition review revealed no method for evaluating the aforementioned. The chromatographic separation was completed on an Agilent Overshadowing XDB-C18, measuring 4.6 mm by 250 mm by five micrometres, with a variable degree starting at zero.Isocratic technique of elution using 1000 ml of 1% trifluoroacetic corrosive in acetonitrile:water (50:50). Utilising a UV indicator at 260.0 nm and LC association programming for statistical study, identification was made. With the aid of ICH guidelines, the created approach received accreditation.

Results: The linearity of the adjustment bend for Dobosuvir in the fixation range of 136-480 g/ml improved. The bend changed immediately for the phosphoryl cycle-related pollutant in the focus range of 10–30 g/ml. The relationship between first place and analyte recognition is reasonable. Dobosuvir's refurbishment time was calculated to be 3.674 minutes, and its contamination time to be 5.704 minutes. Dobosuvir's cycle-related pollution value is zero.043, and its relative trendy deviation value is 1.741. LOD for Dobosuvir and its pollutant were determined to be 0.01% (0.04 g) and 0.03% (0.012 g), respectively. According to my estimation, the LOQ for Dobosuvir and its debasement were 0.5% (0.125 g) and 1.50% (0.375 g).

Conclusion: All of the findings show that the proposed approach was considered to be quite sensitive, basic, real, exact, forceful, and brief. Due to the more limited protection durations, a large number of analyses may be dissected in a more confined amount of time, making it more useful for routine examination of Dobosuvir and related phosphoryl debasement in mass and drug measurements structures.

Views
  • abstarct icon Abstract: 44 Views
  • pdf icon PDF: 10 Views

Downloads

Download data is not yet available.

Downloads

Published

2023-12-21

How to Cite

L, S., V, K. kumar, & P, A. R. (2023). Development and validation of Dosobuvir In RP- HPLC. Frontier Journal of Pharmaceutical Sciences and Research, 6(3), 33–36. Retrieved from https://frontierjournals.org/index.php/fjpsr/article/view/51